PA Main Unit,19″ RACK

SPA-400-V2

1

description

The SPA-400-V2 is part of the SPA-V2 series public address and general alarm system that combines quality and value. The SPA-V2 is an improved second generation system of the version that has been installed in thousands of marine vessels around the world. The basic functionality module can support a single, non-redundant system and is delivered as a 19” rack which contains the main board, plus minimum one amplifier and optional functions.

  • Input & priorities for 3 microphone panels
  • Input from CIS 3130 Talk Back system for PA control
  • Output to CIS Talk Back system
  • Input from entertainment system
  • PABX Input with zone presets
  • 6 zones, 100V, 400W signal output
  • Input for 2 alarm panels
  • 2x Fire alarm input, all call and zone selection (fire crew)
  • Alarm mute during PA message

Optional functions are:

  • Number of michrophone and alarm panels
  • Dual system, redundancy
  • Additional amplifiers
  • Alarm generators
  • PABX Interface
  • Redundant power supply
  • Digital message recorder
  • Chime generator
  • Entertainment
  • Output for voice data recording
  • On delivery, the rack is equipped and internally wired according to customer specifications. The system is tested and passed according to EN60945.
2

Rack size (WxHxD) 525 x 584 x 525 (19” 12HU)
Material Black painted steel
Mounting Floor
Voltage input Mains 230 VAC & 24 VDC (110V AC on req.)
Connections Plugable terminals for max. 2.5mm2 cable
Cable requirements Signal cable 0.75mm2 twisted outer screen
Amplifier 1x VPA-400, details on separate datasheet
Output 100V -400W
Operating temperaure -15 to +55°C
Relative humidity <95%
Safety EN 60065
Tested according EN 60945
Optional rack sizes 19” 12,16, 20,24,30 and 40HU

PA Main Unit,19″ RACK

SPA-400D-V2

1

description

The SPA-400D-V2 is part of the SPA-V2 series Public Address and General Alarm system that combines quality and value. The SPA-V2 is an improved second generation version of the system that has been installed in thousands of marine vessels around the world. SPA-400D-V2 is the latest in the family that comes with our EA1400 Class-D amplifier.

The basic functionality module can support a single, non-redundant system and is delivered as a 19” rack that contains the main board, plus minimum one amplifier and optional functions.

Optional functions are:

  • Microphone and alarm panels
  • Dual system, with redundancy
  • Additional amplifiers
  • Alarm generators
  • PABX Interface
  • Redundant power supply
  • Digital message recorder
  • Chime generator
  • Entertainment
  • Output for voice data recording
2

Rack size (WxHxD) 525 x 584 x 525 (19” 12HU)
Material Black painted steel
Mounting Floor
Voltage input Mains 230 VAC & 230 VAC emergency supply (110V AC on req. for both)
Connections Plugable terminals for max. 2.5mm2 cable
Cable requirements Signal cable 0.75mm2 twisted outer screen
Amplifier 1x EA-1400, details on separate datasheet
Output 100V – 400W (400W music @ 55 °C continuously, 400W alarm @ 55 °C 30 min.)
Operating temperaure -15 to +55°C
Relative humidity <95%
Safety EN 60065
Tested according EN 60945
Optional rack sizes 19” 12,16, 20 and 24HU
PRODUCT VARIANTS
2340130022 SPA-400D-V2 PA MAIN UNIT, 19” RACK, INCL. 400 W CLASS-D AMPLIFIER, 110/110VAC

PA Main Unit,19″ RACK

SPA-120-V2

1

description

  • Input & priorities for 3 microphone panels
  • Input from CIS 3130 Talk Back system for PA control
  • Output to CIS Talk Back system
  • Input from entertainment system
  • PABX Input with zone presets
  • 6 zones 100 V signal output
  • Input for 2 alarm panels
  • 2x Fire alarm input, all call and zone selection (fire crew)
  • Alarm mute during PA message

The SPA series public address and general alarm system combines quality and value. The SPA-V2 is an improved second generation system which in first generation version has been installed in thousands of ships around the world. The basic functionality module can support a single, non-redundant system and delivered as a 19” rack which contains main board, minimum one amplifier and optional functions.

Optional functions are:

  • Number of michrophone and alarm panels
  • Dual system, redundancy
  • Additional amplifiers
  • Alarm generators
  • PABX Interface
  • Redundant power supply
  • Digital message recorder
  • Chime generator
  • Entertainment
  • Output for voice data recording
  • At delivery, the rack is equipped and internally
2

Rack size (WxHxD) 525 x 584 x 525 (19” 12HU)
Material Black painted steel
Mounting Floor
Voltage input Mains 230 VAC & 24 VDC (110V AC on req.)
Connections Plugable terminals for max. 2.5mm2 cable
Cable requirements Signal cable 0.75mm2 twisted outer screen
Amplifier 1x VPA-400, details on separate datasheet
Output 100V -400W
Operating temperaure -15 to +55°C
Relative humidity <95%
Safety EN 60065
Tested according EN 60945
Optional rack sizes 19” 12,16, 20,24,30 and 40HU

SPA-240-V2

1

description

Optional functions are:

  • Input & priorities for 3 microphone panels
  • Input from CIS 3130 Talk Back system for PA control
  • Output to CIS Talk Back system
  • Input from entertainment system
  • PABX Input with zone presets
  • 6 zones 100 V signal output
  • Input for 2 alarm panels
  • 2x Fire alarm input, all call and zone selection (fire crew)
  • Alarm mute during PA message

The SPA series public address and general alarm system combines quality and value. The SPA-V2 is an improved second generation system which in first generation version has been installed in thousands of ships around the world. The basic functionality module can support a single, non-redundant system and delivered as a 19” rack which contains main board, minimum one amplifier and optional functions.

Optional functions are:

  • Number of michrophone and alarm panels
  • Dual system, redundancy
  • Additional amplifiers
  • Alarm generators
  • PABX Interface
  • Redundant power supply
  • Digital message recorder
  • Chime generator
  • Entertainment
  • Output for voice data recording
2

Rack size (WxHxD) 525 x 584 x 525 (19” 12HU)
Material Black painted steel
Mounting Floor
Voltage input Mains 230 VAC & 24 VDC (110V AC on req.)
Connections Plugable terminals for max. 2.5mm2 cable
Cable requirements Signal cable 0.75mm2 twisted outer screen
Amplifier 1x VPA-240, details on separate datasheet
Output 100V -240W
Operating temperaure -15 to +55°C
Relative humidity <95%
Safety EN 60065
Tested according EN 60945
Optional rack sizes 19” 12,16, 20,24,30 and 40HU

Partners