SPA-400-V2
description
The SPA-400-V2 is part of the SPA-V2 series public address and general alarm system that combines quality and value. The SPA-V2 is an improved second generation system of the version that has been installed in thousands of marine vessels around the world. The basic functionality module can support a single, non-redundant system and is delivered as a 19” rack which contains the main board, plus minimum one amplifier and optional functions.
- Input & priorities for 3 microphone panels
- Input from CIS 3130 Talk Back system for PA control
- Output to CIS Talk Back system
- Input from entertainment system
- PABX Input with zone presets
- 6 zones, 100V, 400W signal output
- Input for 2 alarm panels
- 2x Fire alarm input, all call and zone selection (fire crew)
- Alarm mute during PA message
Optional functions are:
- Number of michrophone and alarm panels
- Dual system, redundancy
- Additional amplifiers
- Alarm generators
- PABX Interface
- Redundant power supply
- Digital message recorder
- Chime generator
- Entertainment
- Output for voice data recording
- On delivery, the rack is equipped and internally wired according to customer specifications. The system is tested and passed according to EN60945.
specifications
Rack size (WxHxD) 525 x 584 x 525 (19” 12HU)
Material Black painted steel
Mounting Floor
Voltage input Mains 230 VAC & 24 VDC (110V AC on req.)
Connections Plugable terminals for max. 2.5mm2 cable
Cable requirements Signal cable 0.75mm2 twisted outer screen
Amplifier 1x VPA-400, details on separate datasheet
Output 100V -400W
Operating temperaure -15 to +55°C
Relative humidity <95%
Safety EN 60065
Tested according EN 60945
Optional rack sizes 19” 12,16, 20,24,30 and 40HU
DOWNLOADS
SPA-400D-V2

description
The SPA-400D-V2 is part of the SPA-V2 series Public Address and General Alarm system that combines quality and value. The SPA-V2 is an improved second generation version of the system that has been installed in thousands of marine vessels around the world. SPA-400D-V2 is the latest in the family that comes with our EA1400 Class-D amplifier.
The basic functionality module can support a single, non-redundant system and is delivered as a 19” rack that contains the main board, plus minimum one amplifier and optional functions.
Optional functions are:
- Microphone and alarm panels
- Dual system, with redundancy
- Additional amplifiers
- Alarm generators
- PABX Interface
- Redundant power supply
- Digital message recorder
- Chime generator
- Entertainment
- Output for voice data recording
specifications
Rack size (WxHxD) 525 x 584 x 525 (19” 12HU)
Material Black painted steel
Mounting Floor
Voltage input Mains 230 VAC & 230 VAC emergency supply (110V AC on req. for both)
Connections Plugable terminals for max. 2.5mm2 cable
Cable requirements Signal cable 0.75mm2 twisted outer screen
Amplifier 1x EA-1400, details on separate datasheet
Output 100V – 400W (400W music @ 55 °C continuously, 400W alarm @ 55 °C 30 min.)
Operating temperaure -15 to +55°C
Relative humidity <95%
Safety EN 60065
Tested according EN 60945
Optional rack sizes 19” 12,16, 20 and 24HU
PRODUCT VARIANTS
2340130022 SPA-400D-V2 PA MAIN UNIT, 19” RACK, INCL. 400 W CLASS-D AMPLIFIER, 110/110VAC
DOWNLOADS

SPA-120-V2
description
- Input & priorities for 3 microphone panels
- Input from CIS 3130 Talk Back system for PA control
- Output to CIS Talk Back system
- Input from entertainment system
- PABX Input with zone presets
- 6 zones 100 V signal output
- Input for 2 alarm panels
- 2x Fire alarm input, all call and zone selection (fire crew)
- Alarm mute during PA message
The SPA series public address and general alarm system combines quality and value. The SPA-V2 is an improved second generation system which in first generation version has been installed in thousands of ships around the world. The basic functionality module can support a single, non-redundant system and delivered as a 19” rack which contains main board, minimum one amplifier and optional functions.
Optional functions are:
- Number of michrophone and alarm panels
- Dual system, redundancy
- Additional amplifiers
- Alarm generators
- PABX Interface
- Redundant power supply
- Digital message recorder
- Chime generator
- Entertainment
- Output for voice data recording
- At delivery, the rack is equipped and internally
specifications
Rack size (WxHxD) 525 x 584 x 525 (19” 12HU)
Material Black painted steel
Mounting Floor
Voltage input Mains 230 VAC & 24 VDC (110V AC on req.)
Connections Plugable terminals for max. 2.5mm2 cable
Cable requirements Signal cable 0.75mm2 twisted outer screen
Amplifier 1x VPA-400, details on separate datasheet
Output 100V -400W
Operating temperaure -15 to +55°C
Relative humidity <95%
Safety EN 60065
Tested according EN 60945
Optional rack sizes 19” 12,16, 20,24,30 and 40HU
DOWNLOADS
SPA-240-V2

description
Optional functions are:
- Input & priorities for 3 microphone panels
- Input from CIS 3130 Talk Back system for PA control
- Output to CIS Talk Back system
- Input from entertainment system
- PABX Input with zone presets
- 6 zones 100 V signal output
- Input for 2 alarm panels
- 2x Fire alarm input, all call and zone selection (fire crew)
- Alarm mute during PA message
The SPA series public address and general alarm system combines quality and value. The SPA-V2 is an improved second generation system which in first generation version has been installed in thousands of ships around the world. The basic functionality module can support a single, non-redundant system and delivered as a 19” rack which contains main board, minimum one amplifier and optional functions.
Optional functions are:
- Number of michrophone and alarm panels
- Dual system, redundancy
- Additional amplifiers
- Alarm generators
- PABX Interface
- Redundant power supply
- Digital message recorder
- Chime generator
- Entertainment
- Output for voice data recording
specifications
Rack size (WxHxD) 525 x 584 x 525 (19” 12HU)
Material Black painted steel
Mounting Floor
Voltage input Mains 230 VAC & 24 VDC (110V AC on req.)
Connections Plugable terminals for max. 2.5mm2 cable
Cable requirements Signal cable 0.75mm2 twisted outer screen
Amplifier 1x VPA-240, details on separate datasheet
Output 100V -240W
Operating temperaure -15 to +55°C
Relative humidity <95%
Safety EN 60065
Tested according EN 60945
Optional rack sizes 19” 12,16, 20,24,30 and 40HU